hpacucli
allows control of the RAID array controllers on HP servers.
Installation on CentOS
- Download RPM from HP's website (free account required).
Install, e.g:
yum install hpacucli-9.40-12.0.x86_64.rpm
Usage
Status of All Controllers
To display the status of all RAID controllers:
hpacucli ctrl all show status
Example output:
Smart Array P410i in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
Configuration of All Controllers
To display the configuration of all RAID controllers:
hpacucli ctrl all show config
Example output:
Smart Array P410i in Slot 0 (Embedded) (sn: 5001438001AD7D90)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (136.7 GB, RAID 1, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5123432101AB8D8F)
Status of Logical Drives
To display the status of all logical drives on a specific controller:
hpacucli ctrl slot=0 ld all show status
Example output:
logicaldrive 1 (136.7 GB, 1): OK
Status of all physical drives
To display the status of all physical drives on a specific controller:
hpacucli ctrl slot=0 pd all show status
Example output:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 146 GB): OK